Polling Interval

To configure the polling intervals, click Polling Interval in the UDT Settings page:

  1. In the Orion Web Console, click Settings > All Settings.
  2. Under Product Specific Settings, click UDT Settings.
  3. Click Polling Interval.
Setting Default value Description
Layer 2 Default Poll Interval 30 minutes The frequency of polling for layer 2 devices, such as switches.
Layer 3 Default Poll Interval 30 minutes The frequency of polling for layer 3 devices, such as routers.
Domain controller Default Poll Interval 30 minutes The frequency of polling Active Directory domain controllers for user login information.
Re-Apply Polling Statistics Intervals Button enabled

Click Re-Apply Polling Intervals to apply the specified values for selected entities in this section to all objects in the database.

Click Submit at the bottom of the page to use the current settings for new objects.

If you leave the page without submitting the changes, your settings will be applied to objects in the database, but will not be saved as default. For objects added to the database in the future, the default settings will be used. Not submitting the changes can result in different settings for objects that are already in the database, and different settings for newly added objects.