Lotus Notes monitor
The Lotus Notes monitor verifies that a Lotus Notes mail server can accept incoming sessions, as well as its level of responsiveness.
Use the Lotus Notes monitor to test the following:
- A Lotus Notes client can open a connection with a Lotus Notes server.
- The server adheres to the Lotus Notes protocol by responding with the correct codes.
- The server responds within a required number of seconds.
The monitor opens a connection to the specified Lotus Notes server and waits for the service to respond The test is successful if a valid response is returned within the specified maximum test duration. After it receives a receipt that the message was opened, it safely disconnects from the server. The test is considered failed if the Lotus Notes server fails to respond or responds with an error code indicating that the service is not available.
Create a Lotus Notes monitor
- Click Devices in the toolbar.
- Locate and click the targeted device you want to monitor.
-
In the toolbar, click Add > Add New Monitor.
- In the Select Monitor menu, click Lotus Notes.
-
Under Identification, enter information about the monitor.
-
Enter a name in the Monitor Name field using up to 64 characters. This name will appear in the monitor list, monitor status, log files, and your reports.
You can change this name later, if necessary. ipMonitor does not use this field to internally identify this monitor.
-
Select Enabled to enable the monitor.
When enabled, the monitor tests the specified resource using the settings you enter under Test Parameters. You can disable the monitor later if required.
- Select Store Monitor Statistics for Recent Activity and Historical Reports to enable this functionality.
-
-
Under Test Parameters, enter the monitor testing parameters.
- Enter the IP address or domain name of the Lotus Notes mail server you want to monitor.
- Enter the TCP port number that the targeted resource responds on. The default is TCP port 70.
-
Under Timing, configure the fields for the monitor testing states.
- In the Maximum Test Duration field, enter the maximum test duration rate (in seconds) that the monitor times out before the test is considered a failure.
-
In the remaining fields, enter the number of second between each test while the monitor is in an OK state (Up), a failed state while alerts are processed (Down), and a failed state and the maximum number of alerts have been processed (Lost).
In the Lost state, no additional failure alerts are processed. However, a recovery notification is sent if the monitor recovers.
-
Under Notification Control, complete the fields to determine how many test failures must occur before an alert is sent.
- Enter the number of test failures that occur for each alert before ipMonitor generates an alert for the monitor. The default option is 3.
-
Enter the maximum number of alerts to send before the monitor enters a Lost state.
The monitor must be assigned to a notification alert to generate an action.
-
Under Recovery Parameters, complete the fields to indicate the corrective action used to automatically restore a resource using the External Process Recovery, Reboot Server Recovery, or Restart Service Recovery action.
- Enter the Fully Qualified Domain Name (FQDN), NetBIOS, or IP Address of the machine hosting the service that needs a restart or the machine that needs a restart. You can also click Browse to locate and select the machine.
- Select the set of credentials used by the recovery alert. You can select a specific credential to execute recovery alerts that require access to restricted resources, such as Reboot Server, Restart Service, or External Process.
- Select the list of services to restart on the target machine specified in the FQDN/NetBIOS/IP Address field. This field is only required for the Restart Service alert. If a service has dependencies, select all dependent services.
- Click OK.